Face mask positive pressure | 1.7 to 5.9 mbar |
Demand valve peak flow rate | >500 litres/min–1 |
Approximate weight | 9.5 kg (less face mask) |
Airline/cascade medium air supply pressure |
8 to 10 bar |
When the automatic switch over occurs, an automatic audible alarm (whistle) sounds to alert the wearer they are now being supplied by breathing quality air from the SCBA cylinder.
For faster protection
30, 45 and 60 mins nominal duration. Also available in both Fast Mask and Fast Cowl versions.
And QuickFill high pressure refill coupling
EN: EN 137 : 2006 Type 1 EU DoC EN137 – QFXR EN 137 : 2006 Type 1 ASV EN 14593 – 1 : 2018 EU DoC EN137 – QFXR-ASV / EU DoC EN 14593
UKCA: UKCA EN 137 : 2006 Type 1 UKCA DoC EN137- QFXR UKCA DoC EN137- QFXR-ASV UKCA EN 137 : 2006 Type 1 ASV EN 14593 – 1 : 2018
NIOSH: NIOSH 45 min NIOSH 45 min NIOSH 30 min NIOSH 30 min
AS/NZS: AS/NZS 1716:2012
Face mask positive pressure | 1.7 to 5.9 mbar |
Demand valve peak flow rate | >500 litres/min–1 |
Approximate weight | 9.5 kg (less face mask) |
Airline/cascade medium air supply pressure |
8 to 10 bar |
Storage temperature | +4°C to +30°C |
Operation temperature | –40ºC to +70ºC |
–40ºC when Winter Cover fitted and stored prior to use in accordance with Cam Lock stated range of storage temperatures | |
Maximum humidity | 95% |
Item | Materials |
Harness assembly | Kevlar/Nomex flame resistant material |
Tubular backframe | 316 Stainless Steel |
Medium pressure hose | Reinforced EPDM |
High pressure hose | Stainless Steel braiding c/w PTFE liner and Polyester outer sleeve |
Pigtail hose plug connector | Rectus (CEJN pattern), Foster, Hansen and Stäubli |